Selection of operation mode
(2)
Network operation mode (Pr. 79 setting "0" (initial value), "2")
Select the Network operation mode to give start and frequency commands via CC-Link communication.
Generally, parameter change cannot be performed from the operation panel in the Network operation mode. (Some
parameters can be changed. Refer to the detailed description of each parameter.)
When "0" (initial value) is selected for Pr. 79, the inverter enters the Network operation mode at power-ON.
When frequent parameter changing is necessary, setting "0" (initial value) allows the operation mode to be changed easily
to the PU operation mode by pressing
return to the Network operation mode.
Pr. 79 = "2" sets the Network operation mode to be always selected at power-ON and disables the operation mode change.
(3)
PU operation mode (Pr. 79 setting "1")
(4)
Switch-over mode (Pr. 79 setting "6")
While continuing operation, you can switch between the PU operation and the Network operation (CC-Link communication).
Operation Mode Switching
PU operation
NET operation
NET operation
PU operation
(5)
Valid command in each operation mode
The following table lists valid and invalid commands in each operation mode.
Monitoring and parameter reading are valid in any operation mode.
Command source
Operation panel
CC-Link communication
∗1
Writing of some parameters may be disabled by the Pr.77 Parameter write selection setting and the operating condition. (Refer to page 196)
∗2
Writing of some parameters is enabled regardless of the operation mode and the command source. Writing is also enabled when
(Refer to the parameter list on page 84.) Parameters cannot be cleared.
∗3
Only the PU stop is enabled. PS is displayed on the operation panel during PU stop. The inverter operates according to the Pr.75 Reset selection/PU stop
(
selection setting.
Refer to page 194.
Parameters referred to
Pr. 75 Reset selection/PU stop selection
Pr. 77 Parameter write selection
Pr. 161 Frequency setting/key lock operation selection
104
of the operation panel. When you switched to the PU operation mode, always
Send the mode change command to the Network operation mode through CC-Link communication.
(Rotation direction and set frequency are the same as those of PU operation.)
Select the PU operation mode with the operation panel.
(The rotation direction and frequency command in the Network operation mode are used unchanged.)
Operation mode
Item
Operation (start) command
Operation (stop) command
Running frequency
Parameter writing
Inverter reset
Operation (start) command
Operation (stop) command
Running frequency
Parameter writing
Inverter reset
)
Refer to page 194
Refer to page 196
Select the PU operation mode when applying start and
frequency command by only the key operation of the
operation panel. Also select the PU operation mode when
making communication using the PU connector.
When "1" is selected for Pr. 79, the inverter enters the PU
operation mode at power ON. You cannot change to the
other operation mode.
The setting dial of the operation panel can be used for
setting like a potentiometer. (Refer to Pr. 161 Frequency
setting/key lock operation selection (page 224))
Switching Operation/Operating Status
PU operation
∗1
×
×
×
×
∗2
×
: Valid ×: Invalid Δ: Partially valid
Refer to page 224
NET operation
×
Δ
∗3
×
×
∗2
×
∗1
Pr.77
= "2."