2.2

Main circuit terminal specifications

2.2.1

Specification of main circuit terminal

Terminal
Terminal Name
Symbol
R/L1,
S/L2,
AC power input
T/L3 ∗1
U, V, W
Inverter output
P/+, PR
Brake resistor connection
P/+, N/-
Brake unit connection
P/+, P1
DC reactor connection
Earth (Ground)
∗1
When using a single-phase power input model, terminals are R/L1 and S/L2.
2.2.2
Terminal arrangement of the main circuit terminal, power supply and the motor
wiring
Three-phase 200V class
FR-E720-0.1KNC to 0.75KNC
N/-
R/L1 S/L2 T/L3
Power supply
FR-E720-5.5KNC, 7.5KNC
R/L1 S/L2 T/L3
N/-
Power supply
Connect to the commercial power supply.
Connect a three-phase squirrel-cage motor.
Connect a brake resistor (FR-ABR, MRS type, MYS type) across terminals P/+ and
PR.
(The brake resistor cannot be connected to the 0.1K or 0.2K.)
Connect a brake unit (FR-BU2).
Remove the jumper across terminals P/+ and P1 and connect a DC reactor.
For earthing (grounding) the inverter chassis. Must be earthed (grounded).
Jumper
P/+
PR
IM
Motor
P/+ PR
Jumper
IM
Motor

Main circuit terminal specifications

Description
FR-E720-1.5KNC to 3.7KNC
Jumper
N/- P/+
R/L1 S/L2 T/L3
PR
Power supply
FR-E720-11KNC, 15KNC
R/L1 S/L2 T/L3
N/-
Power supply
IM
Motor
P/+
PR
Jumper
IM
Motor
15