Useful functions
5.21.5 USB communication (Pr. 547, Pr. 548, Pr. 551)
Inverter setup can be easily performed using the FR Configurator by connecting the inverter and personal computer
with a USB cable.
A personal computer and inverter can be easily connected with one USB cable.
Parameter
Name
Number
USB communication
547
∗1
station number
USB communication
548
∗1
check time interval
PU mode operation
551
command source
∗2
selection
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 197)
∗1
Changed setting value is valid when powering on or resetting the inverter.
∗2
This parameter can be changed during a stop in any operation mode.
(1)
USB communication specifications
Interface
Conforms to USB1.1
Transmission
12Mbps
Speed:
Wiring Length
Maximum 5m
Connector
USB mini B connector (receptacle mini B type)
Power supply
Self-power supply
You can perform parameter setting and monitoring with the FR Configurator. Refer to the instruction manual of the FR
Configurator for details.
220
Initial Value
Setting Range
0
9999
0.1 to 999.8s
9999
USB connector
USB cable
<How to open the USB connector cover>
Pull the cover in the direction of arrow.
0 to 31
Inverter station number specification
USB communication is possible
0
Trips in the PU operation mode (E.USB)
Sets the interval of communication check time.
If a no-communication state persists for longer than
the permissible time, the inverter trips (E.USB).
9999
No communication check
2
For manufacturer setting. Do not set.
USB connector is the command source when PU
3
operation mode.
Operation panel is the command source when PU
4
operation mode.
USB automatic recognition
Normally, operation panel is the command source.
9999
When USB is connected, USB connector is the
command source.
Then turn it upward.
Description