REMARKS
USB cable available on the market
Name
USB cable
(2)
Select the command source of the PU operation mode (Pr. 551)
Either the operation panel, or USB connector can be specified as the command source in the PU operation mode.
You can write parameters and monitor different items with FR Configurator through the USB connector. To do that, set
Pr.551 = "9999 (initial value) or 3" in PU operation mode.
NOTE
Changed setting value is valid when powering ON or resetting the inverter.
All of the operation mode indicator (
operation panel.
PU...PU operation mode, NET...network operation mode, —....without command source
Pr. 551
Setting
Operation panel
3
4
PU
9999
PU ∗
(initial value)
∗ When Pr. 551 = "9999", the priorities of the PU command source is USB connector > operation panel.
Model
MR-J3USBCBL3M
Connector for amplifier
mini-B connector (5 pin)
Cable length 3m
) of the operation panel turns OFF when command source is not
Command Source
USB connector
PU
PU ∗
Application/Specifications
Connector for personal computer
A connector
CC-Link communication
NET
NET
NET
Useful functions
221