Parameter list
Func-
Parameter
Name
tion
156
Stall prevention operation selection
157
OL signal output timer
 160
User group read selection
Frequency setting/key lock operation
161
selection
Automatic restart after instantaneous
162
power failure selection
Stall prevention operation level for
165
restart
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
171
Operation hour meter clear
User group registered display/batch
172
clear
173
User group registration
174
User group clear
178
Parameter for manufacturer setting. Do not set.
179
180
RY4 function selection
181
RY3 function selection
182
RY2 function selection
183
RY9 function selection
184
RYB function selection
190
RX2 (terminal Y0) function selection
191
RX6 function selection
192
RX7 function selection
232
Multi-speed setting (speed 8)
233
Multi-speed setting (speed 9)
234
Multi-speed setting (speed 10)
235
Multi-speed setting (speed 11)
236
Multi-speed setting (speed 12)
237
Multi-speed setting (speed 13)
238
Multi-speed setting (speed 14)
239
Multi-speed setting (speed 15)
240
Soft-PWM operation selection
241
Parameter for manufacturer setting. Do not set.
90
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0 to 31, 100, 101
1
0
120
0 to 25s, 9999
0.1s
0s
120
0, 1, 9999
1
0
197
0, 1, 10, 11
1
0
224
0, 1, 10, 11
1
1
180
0 to 200%
0.1%
150%
180
0, 10, 9999
1
9999
176
0, 9999
1
9999
176
9999, (0 to 16)
1
0
197
0 to 999, 9999
1
9999
197
0 to 999, 9999
1
9999
197
1
0
163
1
1
163
0 to 5, 7, 8, 10, 12,
1
2
163
14 to 16, 18, 24, 25,
62, 65 to 67, 9999
1
24
163
1
62
163
0, 1, 3, 4, 7, 8, 11 to 16,
20, 25, 26, 46, 47, 64,
1
0
167
68 , 80 , 81
90, 91, 93,
95, 96, 98, 99, 100, 101,
103, 104, 107, 108,
111 to 116, 120, 125,
126, 146, 147, 164, 168,
1
4
167
180
181
190, 191, 193,


195, 196, 198, 199,
9999
0, 1, 3, 4, 7, 8, 11 to 16,
20, 25, 26, 46, 47, 64,
68, 80, 81
90, 91, 95,
96, 98, 99, 100, 101,
103, 104, 107, 108,
1
99
167
111 to 116, 120, 125,
126, 146, 147, 164, 168
180
181
190, 191, 195,

196, 198, 199, 9999
0 to 400Hz, 9999
0.01Hz
9999
130
0 to 400Hz, 9999
0.01Hz
9999
130
0 to 400Hz, 9999
0.01Hz
9999
130
0 to 400Hz, 9999
0.01Hz
9999
130
0 to 400Hz, 9999
0.01Hz
9999
130
0 to 400Hz, 9999
0.01Hz
9999
130
0 to 400Hz, 9999
0.01Hz
9999
130
0 to 400Hz, 9999
0.01Hz
9999
130
0, 1
1
1
192
Customer
Parameter
Setting
Read
156
38
157
39
 160
00
161
01
162
02
165
05
168
Parameter for manufacturer setting. Do not set.
169
170
0A
171
0B
172
0C
173
0D
174
0E
178
Parameter for manufacturer setting. Do not set.
179
180
14
181
15
182
16
183
17
184
18
190
1E
191
1F
192
20
232
28
233
29
234
2A
235
2B
236
2C
237
2D
238
2E
239
2F
240
30
241
Parameter for manufacturer setting. Do not set.
Instruction Code
Control Mode-based Correspondence
Write
Extended
V/F
V/F
V/F
AD MFVC
AD MFVC
AD MFVC
B8
1
B9
1
80
2
81
2
82
2
85
2
8A
2
8B
2
8C
2
8D
2
8E
2
94
2
95
2
96
2
97
2
98
2
9E
2
9F
2
A0
2
A8
2
A9
2
AA
2
AB
2
AC
2
AD
2
AE
2
AF
2
B0
2
Parameter list
Parameter
Clear
All clear
GP MFVC
GP MFVC
GP MFVC
5

Advertisement

Table of Contents
loading