Mitsubishi Electric FR-E720-0.1KNC Instruction Manual page 99

Table of Contents

Advertisement

Parameter list
Func-
Parameter
Name
tion
244
Cooling fan operation selection
245
Rated slip
246
Slip compensation time constant
Constant-power range slip
247
compensation selection
249
Earth (ground) fault detection at start
250
Stop selection
251
Output phase loss protection selection
255
Life alarm status display
256
Inrush current limit circuit life display
257
Control circuit capacitor life display
258
Main circuit capacitor life display
259
Main circuit capacitor life measuring
261
Power failure stop selection
267
Parameter for manufacturer setting. Do not set.
268
Monitor decimal digits selection
269
Parameter for manufacturer setting. Do not set.
270
Stop-on contact control selection
Stop-on contact excitation current low-
275
speed multiplying factor
PWM carrier frequency at stop-on
276
contact
Stall prevention operation current
277
switchover
278
Brake opening frequency
279
Brake opening current
280
Brake opening current detection time
281
Brake operation time at start
282
Brake operation frequency
283
Brake operation time at stop
286
Droop gain
287
Droop filter time constant
292
Automatic acceleration/deceleration
Acceleration/deceleration separate
293
selection
295
Magnitude of frequency change setting
296
Password lock level
297
Password lock/unlock
298
Frequency search gain
Rotation direction detection selection
299
at restarting
 313
RX9 function selection
 314
RXA function selection
 315
RXB function selection
92
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0, 1
1
1
213
0 to 50%, 9999
0.01%
9999
119
0.01 to 10s
0.01s
0.5s
119
0, 9999
1
9999
119
0, 1
1
0
190
0 to 100s,
1000 to 1100s,
0.1s
9999
157
8888, 9999
0, 1
1
1
190
(0 to 15)
1
0
214
(0 to 100%)
1%
100%
214
(0 to 100%)
1%
100%
214
(0 to 100%)
1%
100%
214
0, 1 (2, 3, 8, 9)
1
0
214
0, 1, 2
1
0
186
0, 1, 9999
1
9999
176
0, 1
1
0
158
0 to 300%, 9999
0.1%
9999
158
0 to 9, 9999
1
9999
158
0, 1
1
0
120
0 to 30Hz
0.01Hz
3Hz
160
0 to 200%
0.1%
130%
160
0 to 2s
0.1s
0.3s
160
0 to 5s
0.1s
0.3s
160
0 to 30Hz
0.01Hz
6Hz
160
0 to 5s
0.1s
0.3s
160
0 to 100%
0.1%
0%
210
0 to 1s
0.01s
0.3s
210
0, 1, 7, 8, 11
1
0
140
0 to 2
1
0
140
0, 0.01, 0.1, 1, 10
0.01
0
226
0 to 6, 99, 100 to 106,
1
9999
199
199, 9999
(0 to 5), 1000 to 9998,
1
9999
199
9999
0 to 32767, 9999
1
9999
180
0, 1, 9999
1
0
180
0, 1, 3, 4, 7, 8, 11 to 16,
1
9999
167
20, 25, 26, 46, 47, 64,
68, 80, 81

90, 91, 93,
95, 96, 98, 99, 100, 101,
1
9999
167
103, 104, 107, 108,
111 to 116, 120, 125,
126, 146, 147, 164, 168,
180
181
190, 191, 193,

1
9999
167
195, 196, 198, 199,
9999
Customer
Parameter
Setting
Read
244
34
245
35
246
36
247
37
249
39
250
3A
251
3B
255
3F
256
40
257
41
258
42
259
43
261
45
267
Parameter for manufacturer setting. Do not set.
268
4C
269
Parameter for manufacturer setting. Do not set.
270
4E
275
53
276
54
277
55
278
56
279
57
280
58
281
59
282
5A
283
5B
286
5E
287
5F
292
64
293
65
295
67
296
68
297
69
298
6A
299
6B
 313
0D
 314
0E
 315
0F
Instruction Code
Control Mode-based Correspondence
Write
Extended
V/F
V/F
V/F
AD MFVC
AD MFVC
AD MFVC
B4
2
B5
2
B6
2
B7
2
B9
2
BA
2
BB
2
BF
2
C0
2
C1
2
C2
2
C3
2
C5
2
CC
2
CE
2
D3
2
D4
2
D5
2
D6
2
D7
2
D8
2
D9
2
DA
2
DB
2
DE
2
DF
2
E4
2
E5
2
E7
2
E8
2
E9
2
EA
2
EB
2
8D
3
8E
3
8F
3
Parameter list
Parameter
Clear
All clear
GP MFVC
GP MFVC
GP MFVC
5


Advertisement

Table of Contents
loading