Onboard Charger Fault Codes - Club Car Carryall 300 2018 Maintenance And Service Manual

Gasoline vehicle with subaru ex40 engine electric vehicle with eric charging system
Table of Contents

Advertisement

15
Charger Troubleshooting

ONBOARD CHARGER FAULT CODES

The "E" and "F" codes will appear in the display panel followed by three numbers and a period to indicate the different
conditions.
_
ONBOARD CHARGER FAULT CODES
FAULT CODE
F-0-0-1
F-0-0-2
F-0-0-3
F-0-0-4
F-0-0-5
F-0-0-6
E-0-0-1
E-0-2-1
E-0-0-2
E-0-2-2
E-0-0-3
E-0-0-4
E-0-0-5
E-0-0-6
TABLE CONTINUED ON NEXT PAGE
Page 15-18
2018 Carryall 300 Maintenance and Service Manual
DESCRIPTION
Internal charger fault
Battery high voltage
Battery low voltage
Charge timeout caused by battery pack not reaching
required voltage within safe time limit
Battery could not meet minimum voltage
Charger temperature limit exceeded
Low AC voltage error
BATTERY CHARGER: FOR ERIC
CHARGING SYSTEM
SOLUTIONS
• Remove the AC power supply and the battery for
a minimum of 30 seconds.
• Check the battery voltage and cable connections.
• Check the battery size and condition.
• This error will automatically clear once the condi-
tion has been corrected.
• Check the battery voltage and cable connections.
• Check the battery size and condition.
• This error will automatically clear once the condi-
tion has been corrected.
Possible causes: Charger output reduced due to
high temperatures, poor battery health, discharged
battery, and/or the battery is not connected correctly.
• Operate at lower ambient temperature.
• Replace the battery pack.
• Check the DC connections.
• This error will automatically clear once the
charger is reset by cycling DC.
• Check for shorted or damaged cells.
• Replace the battery pack.
• This error will automatically clear once the
charger is reset by cycling DC.
• Ensure sufficient cooling air flow and reset the
charger by disconnecting the AC cord for 10 min-
utes. Reconnect the AC cord.
• This error will automatically clear once the condi-
tion has been corrected.
• Connect the charger to an AC source that pro-
vides stable AC between 85 - 270 VAC / 45 - 65
Hz.
• This error will automatically clear once the condi-
tion has been corrected.