10 Appendix
Parameter
Communication
DC connection type
AC connection type
Grid Support
(1) The voltage difference between MPPTs should be less than 150 V. The voltage of the
configured string should be higher than the lower limit of the rated MPPT voltage.
Parameter
Input (DC)
Recommended max. PV in-
put power
Max. PV input voltage
Min. operating PV voltage /
Start-up input voltage
Rated PV input voltage
MPP voltage range
MPP voltage range for
rated power
No. of independent MPP
inputs
Default No. of PV strings
per MPPT
Max. PV input current
Max.DC Short-circuit
current
Output (AC)
Rated AC output power
Max. AC output power
Rated AC output current (at
230 V)
Max. AC output current
Rated AC voltage
AC voltage range
110
SG5.0RS-ADA
Ethernet / WLAN / RS485 / DI (Ripple control & DRM)
MC4 (Max. 6 mm
2
)/MC4 Compatible Connector (Max. 6
mm
2
)
Plug and play connector (Max. 16 mm
Active & reactive power control and power ramp rate
control
SG9.0RS
13.5 kWp
600 V
40 V / 50 V
360 V
40 V – 560 V
280 V – 480 V
(1)
3
1
48 A(16 A / 16 A / 16 A)
60 A(20 A / 20 A / 20 A)
9000 W
9000 VA
39.2 A
41 A
220 V / 230 V / 240 V
154 V - 276 V
User Manual
SG8.0RS
2
)
SG10RS
15 kWp
310 V – 480 V
(1)
10000 W
9999 W for Australia
10000 VA
9999VA for Australia
43.5 A
45.5 A