5 Electrical Connection
The inverter is equipped with a RJ45 terminal for connecting the external DRED. As shown
in the following figure, pin 5 and pin 6 are used for asserting the DRM0 mode.
step 1 (Optional) Strip the insulation layer of the communication cable with an Ethernet wire strip-
per, and lead the corresponding signal cables out. Insert the stripped communication cable
into the RJ45 plug in the correct order, and crimp it with a crimper.
Skip this step if a standard network cable with RJ45 plug is prepared.
step 2 Unscrew the swivel nut from the connector.
56
1: RJ45 plug
User Manual
2:Protective cap