Installation Setup > 0-10 V Input > Parameters, Counters, Signals; Installation Setup > Appliance Status > Parameters, Counters, Signals - DeDietrich MIT-M /E Installation, User And Service Manual

Reversible packaged air source heat pump
Table of Contents

Advertisement

Tab.90
Adv. Parameters
ADV parameter
Description of the ADV advanced parameters
Sensor input config
Sets the general configuration of the sensor input Tsyst1
(EP036)
Disabled
DHW tank
DHW tank top
Buffer tank sensor
Buffer Tank top
System (cascade)
Sensor input config
Sets the general configuration of the sensor input Tsyst2
(EP037)
Disabled
DHW tank
DHW tank top
Buffer tank sensor
Buffer Tank top
System (cascade)
Tab.91
EP : Entry Parameters = Input parameters
Parameter
Description
SCB func. 10V
Smart Control Board function 10 Volt PWM input
PWMin (EP014)
Off
Temperature control
Power control
Max Setp Temp
Sets the minimum set point temperature for 0 - 10 volts for the Smart Control
0-10V (EP030)
Board
Can be set from 0 °C to 100 °C
Min Setp Power
Sets the maximum set point temperature for 0 - 10 volts for the Smart Control
0-10V (EP031)
Board
Can be set from 0.5 °C to 100 °C
Min Setp Volt 0-10V
Minimum voltage for 0-10 V input corresponding to the minimum set point
(EP034)
Can be set from 0 V to 10 V
Max Setp Volt 0-10V
Maximum voltage for 0-10 V input corresponding to the maximum set point
(EP035)
Can be set from 0 V to 10 V
7756241 - v02 - 19062020
7.4.11
Installation Setup > 0-10 V input > Parameters, counters,
signals
7.4.12
Installation Setup > Appliance status > Parameters,
counters, signals
EP : Entry Parameters = Input parameters
7 Settings
Factory setting
SCB-10
Disabled
Disabled
Factory setting
SCB-10
Off
0
100
0.5
10
MIT-M