Connecting An On/Off Or Modulating Thermostat; Configuring A Thermostat With A Heating/Cooling Control Contact - DeDietrich MIT-M /E Installation, User And Service Manual

Reversible packaged air source heat pump
Table of Contents

Advertisement

Tab.45
Access
CIRCA0,
, CIRCA1,
21.7
19.8
CIRCB1 or CIRCC1 > Set
Screed Drying
Tab.46
Configuration of the R-Bus input for using an on/off thermostat (dry contact)
Access
Parameter
CIRCA0,
OTH LogicLev
21.7
19.8
CIRCA1, CIRCB1
contact (CP640,
or CIRCC1 >
CP641, CP643)
Parameters,
RevContactOTH
counters, signals >
cool (CP690,
Parameters
CP691, CP693)
Tab.47
OTH LogicLev contact and RevContactOTH cool parameter settings
Value of the OTH LogicLev
contact parameter (CP640,
CP641, CP643)
Closed (default value)
Open
Closed
Open
7756241 - v02 - 19062020
1. Set the parameters for the CIRCA0 and CIRCA1, CIRCB1 or CIRCC1
circuits.
On
Parameter
Zone screed drying
(CP470)
ScreedStartTemp
(CP480)
ScreedStopTemp
(CP490)
The screed drying programme will start immediately and continue for the
selected number of days.
At the end of the programme, the selected operating mode will restart.
7.3.14
The on/off or modulating thermostat is connected to the R-Bus terminals
on the EHC–05 PCB or the optional SCB-10 PCB.
The PCBs are delivered with a bridge on the R-Bus terminals.
The R-Bus input can be configured to add the flexibility of using several
types of on/off thermostat or OpenTherm (OT).
1. Configure the parameters for the circuit concerned:
On
Description
Configuration of the on/off input contact direction for heating mode.
Closed (default value): heating demand when contact is closed
Open: heating demand when contact is open
Reversal of the direction of the logic in cooling mode compared to heating mode
No (default value): cooling demand uses the same logic as the heating demand
Yes: cooling demand uses the reverse logic to the heating demand
Value of the RevContactOTH
cool parameter (CP690,
CP691, CP693)
No (default value)
No
Yes
Yes
7.3.15
The AC thermostat (air conditioning) is always connected to the R-Bus
and BL1 terminals on the EHC–05 PCB. The AC thermostat is only
compatible with configurations with a single heating circuit.
Priority will be given to the AC thermostat input over the other Summer/
Winter modes (Auto/Manual).
The PCBs are delivered with a bridge on the R-BUS terminals.
Description
Setting of the screed drying
program of the zone
Setting of the start
temperature of the screed
drying program of the zone
Setting of the stop
temperature of the screed
drying program of the zone

Connecting an on/off or modulating thermostat

Position of the on/off contact
for heating
Closed
Open
Closed
Open
Configuring a thermostat with a heating/cooling control
contact
7 Settings
Adjustment required
Number of days of dry­
1
ing
Drying start temperature
2
Drying end temperature
3
Position of the on/off contact
for cooling
Closed
Open
Open
Closed
MIT-M
55