7 Settings
Fig.43
Influence of outdoor temperatures
and bi-valency.
+
T
C
1
S
+
C
T
S
1
T
1
Tab.41
Access
Air Src Heat pump >
23.5
Parameters, counters,
signals> Parameters
Air Src Heat pump >
23.5
Parameters, counters, signals
> Adv. Parameters
52
MIT-M
C
T
T
2
C
T
T
2
C
T
T
C
2
S
MW-5000542-1
1. Configure the heat pump parameters
On
Parameter
Bivalent temperature
(HP000)
Hybrid mode
(HP061)
Peak elec. cost
(HP062)
Off-peak elec. cost
(HP063)
Gas or oil cost
(HP064)
Min. Outdoor T. HP (HP051)
C COP: Coefficient of performance
C
Coefficient of performance threshold: If the coefficient of
S
performance of the heat pump is higher than the coefficient of
performance threshold, the heat pump takes priority. Otherwise
only the boiler back-up is enabled. The heat pump coefficient of
performance depends on the outdoor temperature and the heating
water set point temperature.
T Outdoor temperature
T
Min. Outdoor T. HP (HP051) parameter: Minimum outdoor
1
temperature below which the compressor of the Heat Pump is
stopped
T
Bivalent temperature parameter (HP000): Bivalent temperature
2
Description
Bivalent temperature
Hybrid mode selection to
choose on what basis the
hybrid system will optimise
Peak rate electricity cost (in
cents)
Off-peak electricity cost (in
cents)
Cost of gas per m3 or oil per
litre (in cents)
Minimum outdoor temperature
below which the compressor
of the Heat Pump is stopped
Adjustment required
5 °C
Set according to the optimisa
tion required. See following
table.
No Hybrid
Hybrid Cost
Primary Energy
Hybrid CO2
Enter the price of electricity at
peak rate.
By default: 15 euro cents.
Enter the price of electricity at
off-peak rate.
By default: 13 euro cents.
Enter the price of fuel.
By default: 80 euro cents.
Retain the default value:
-20 °C.
7756241 - v02 - 19062020