5.3

Shut-down

5.4

Frost Protection

6

Settings

6.1

List of parameters

6.1.1

User Level

7611407 - v07 - 14022022
16
18
20
22
24
FRANCAIS
MW-C002286-C
3. The first time the boiler is powered up, the LANGUAGE parameter is
displayed. Select the desired language by turning the settings button.
4. Confirm the selection by pressing the settings button. The heat pump
begins an automatic venting cycle that lasts around 3 minutes and is
repeated each time the power is cut. If there is a problem, the error is
displayed on the screen.
5. Check the hydraulic pressure in the installation shown on the control
panel display. Recommended hydraulic pressure between 0.15 and
0.2 MPa (1.5 and 2.0 bar).
6. Close the control panel flap.
Important
Give priority to the HOLIDAYS operating mode if the central
heating system is not used for a long period. When this operating
mode is activated:
The electrical circuits continue to be powered up.
The frost protection function is activated.
1. Open the control panel flap.
2. Shut down the heat pump by throwing the ON/OFF switch.
If the central heating system is not in use and there is a risk of frost, we
recommend activating the heat pump's frost protection function. To do this,
activate the mode HOLIDAYS :
1. Press the MODE key.
2. Select HOLIDAYS mode and confirm the selection.
The integrated frost protection device is now activated.
If the temperature of the heating water in the heat pump falls too much,
the integrated protection device switches itself on. This device functions as
follows:
If the water temperature is lower than 7°C, the circulating pump starts
up.
If the water temperature is lower than 4°C, the heat pump starts up.
If the water temperature is higher than 15 °C, the heat pump shuts down
and the circulating pump continues to run for a short time.
Important
To prevent the radiators and the installation from freezing in areas
where that risk exists (in a garage, equipment room, etc.), it is
possible to connect the heat pump to a frost protection thermostat
or an outside temperature sensor.
Menus available at User level:
Access keys
Menus
TEMPERATURE
MODE
Operating mode
6 Settings