DeDietrich MIT-M /E Installation, User And Service Manual page 84

Reversible packaged air source heat pump
Table of Contents

Advertisement

8 Connection and installation examples
EHC
4
X25
X19
14
3 X19: Control signal for the immersion heater, used to
control the immersion heater on the domestic hot
water tank with the EH904 kit
3 X12: 24 V power supply for the condensation sensor,
used to control the immersion heater on the
domestic hot water tank with the EH904 kit
4 X25: Reversal valve from the EH812 reversal valve
kit: A0/domestic hot water circuit
5 Flow sensor – B1 circuit
6 Three-way valve – B1 circuit
84
MIT-M
CIRC
CIRC
A0
B1
AD32
AD32
AD32
AD32
AD324
AD32
AD32
AD32
AD32
AD324
4
4
4
4
4
4
4
AD32
AD32
AD32
AD32
AD32
AD32
AD324
AD324
AD32
10
12
13
9
5
HK150
HK150
HK21
HK21
HK21
HK21
400V~50Hz
400V~50Hz
230V~50Hz
230V~50Hz
EH19
EH19
14
BUS
BUS
BUS
11
10
3
29
8
4
4
4
4
4
4
4
4
4
4
4
4
6
M
M
M
M
7
A/B
A/B
A/B
4
B
B
A
A
A
A
A
A
A
A
A
M
M
EH812
EH812
EH812
EH812
11
AD212
AD212
SCB
6
7
9
7 Power supply for the B1 circuit pump
8 Domestic hot water recirculating pump
9 Safety thermostat for underfloor heating flow
10 X12 R-Bus: SMART TC° connected room thermostat
on the A0 circuit
11 X28 Tdhw2: AD212 domestic hot water sensor
12 SMART TC° connected room thermostat on the B1
circuit
13 Outdoor temperature sensor
14 X23: Outdoor unit bus connection
1. Connect the accessories and options to the EHC–05 PCB, respecting
the 230-400 V and 0-40 V cable feed-throughs.
2. Connect the accessories and options to the SCB-10 PCB, respecting
the 230-400 V and 0-40 V cable feed-throughs.
The icons corresponding to the CIRCB1 circuit and domestic hot
water appear on the user interface. The CIRCA0 circuit icon is
present by default.
8
3
EH904
EH904
MW-1001719-1
13
7756241 - v02 - 19062020
12
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mit-m /hMono awhp 6 mrMono awhp 8 mrMono awhp 11 mr

Table of Contents