Reducing The Noise Level Of The Outdoor Unit; Configuring The Maintenance Message - DeDietrich MIT-M /E Installation, User And Service Manual

Reversible packaged air source heat pump
Table of Contents

Advertisement

Tab.73
Access
Air Src Heat pump >
23.5
Parameters, counters, signals >
Parameters > Adv. Parameters
Tab.74
Access
Air Src Heat pump >
23.5
Parameters, counters, signals >
Parameters > Adv. Parameters
Tab.75
Access
Air Src Heat pump >
23.5
Parameters, counters, signals >
Parameters > Adv. Parameters
7756241 - v02 - 19062020
4. Configure the BL function parameters (AP001) and (AP100).
On
Parameter
BL function
(AP001)
BL2 function
(AP100)
The heat pump is ready to receive and manage Smart Grid signals.
5. Choose the directions of the BL1 IN and BL2 IN multifunction inputs
by setting the BL1 contact config. (AP098) and BL2 contact config.
On
(AP099) parameters.
Parameter
BL1 contact config.
(AP098)
BL2 contact config.
(AP099)
6. Configure the temperature offsets for the voluntary overheating by
configuring the Offset heating - PV (HP091) and Offset DHW - PV
On
(HP092) parameters.
Parameter
Offset heating - PV
(HP091)
Offset DHW - PV
(HP092)
7.3.21
Silent mode is used to reduce the noise level on the outdoor unit during
programmed hours, particularly at night. This mode gives temporary
precedence to silent running rather than temperature control.
1. Connect the silent running kit (package EH829) to the outdoor unit.
2. Connect the silent running kit (package EH829) to one of the CIRCA1,
CIRCB1, CIRCC1 or CIRCAUX1 zone pump outlets of the SCB-10
PCB.
3. Set the timer programming for this zone: silent mode corresponds to
the Sleep activity.
7.3.22
The heat pump user interface is used to display a message whenever
maintenance is necessary.
To configure the maintenance message:
1. Select the
On
2. Select Service notification.
Adjustment required
Smart Grid ready
Smart Grid ready
Adjustment required
BL1 input contact configuration
0 = input active on Open contact
1 = input active on Closed contact
BL2 input contact configuration
0 = input active on Open contact
1 = input active on Closed contact
Adjustment required
Heating setpoint temperature offset when photovoltaic
energy is available
Domestic hot water setpoint temperature offset when
photovoltaic energy is available

Reducing the noise level of the outdoor unit

Configuring the maintenance message

Service Status icon.
7 Settings
MIT-M
63