External Analyzer Specifications

External Analyzer Specifications
External State Analyzer Specifications
480
Threshold Accuracy = +/- 50 mV.
Dynamic Range = +/- 10 V about threshold setting.
Minimum Input Swing = 600 mV pp.
Minimum Input Overdrive = 250 mV or 30% of threshold setting, whichever is
greater.
Absolute Maximum Input Voltage = +/- 40 V.
Probe Input Resistance = 100K ohms +/- 2%.
Probe Input Capacitance = approximately 8 pF.
Maximum +5 Probe Current = 0.650 A.
+5 Probe Voltage Accuracy = +5.0 +/- 5%.
Data Setup Time = 10 ns min.
Data Hold Time = 0 ns, typical.
Qualifier Setup Time = 20 ns min.
Qualifier Hold Time = 10 ns, typical.
Minimum Clock Width = 10 ns
Minimum Clock Period:
– No Tagging Mode = 40 ns (25 Mhz clock).
– Event Tagging Mode = 50 ns (20 MHz clock).
– Time Tagging Mode = 60 ns (16 MHz clock).
Minimum Time from Slave Clock to Master Clock = 10 ns.
Minimum Time from Master Clock to Slave Clock = 50 ns.