HP 64767 User Manual page 446

Emulation/analysis
Table of Contents

Advertisement

Chapter 13: Error Messages
Graphical/Softkey Interface Messages - Unnumbered
No valid trace data
Cause: You tried to store trace data before a trace was completed.
Action: Wait until valid trace data is available before attempting to store a trace.
Not a valid trace file - load aborted
Cause: You tried to load a file.TR that was not created by the emulation session.
Action: Only load trace data files that were created by the emulator.
Not compatible trace file - load aborted
Cause: You tried to load a file.TR that was created by another type of emulator.
Action: Only load trace data files that were created by the same type of emulator.
Number of lines not in range: 1 <= valid lines <= 50
Cause: You tried to enter a number of lines that was outside the range from 1 to 50.
Action: Try entering the command again using a valid number of lines.
Number of spaces not in range: 2 <= valid spaces <= 15
Cause: You tried to enter a number of spaces outside the range from 2 to 15.
Action: Try entering the command again using a valid number of spaces.
opcode extends beyond specified address range
Cause: Memory disassembly is attempted on an address range that is too small.
Action: Display memory mnemonic using a large address range, or no address
range at all.
Perfinit - Absolute file (database) must be loaded line <LINE NUMBER>
Cause: No symbolic data base has been opened (or exists) for the target file when
you executed the "performance_measurement_initialize" command.
Action: Make sure a data base has been loaded for the target file.
446

Advertisement

Table of Contents
loading

This manual is also suitable for:

80186/8/xl/ea/eb

Table of Contents