Chapter 13: Error Messages
Terminal Interface Messages
155
Range terms must be in same segment
Cause: This error occurs when specifying an address range (<segment:offset> thru
<segment:offset>) and the two segment values are different.
Action: Make sure the segment values are the same when specifying address
ranges using logical values.
161
IRET stack conflicts with Peripheral Control Block Location
Cause: An IRET instruction (which pops the IP, CS, and flag values from the
stack) is used when running or stepping user code. This error occurs when the
segment stack pointer points to the Peripheral Control Block.
Action: Either change the value of the segment stack pointer or relocate the
Peripheral Control Block.
193
i80C186/8Ex firmware not compatible with emulation probe
Cause: This status message indicates that the i80C186/8Ex emulator probe is not
properly connected to the cable coming from the emulator control card in the
frame. This renders the emulator completely unuseable.

General Emulator and System Messages

204
FATAL SYSTEM SOFTWARE ERROR
205
FATAL SYSTEM SOFTWARE ERROR
208
FATAL SYSTEM SOFTWARE ERROR
Cause: The system has encountered an error from which it cannot recover.
Action: Write down the sequence of commands which caused the error. Cycle
power on the emulator and reenter the commands. If the error repeats, call your
local HP Sales and Service office for assistance.
206
Incompatible compatibility table entry
Cause: The emulation firmware (ROM) is not compatible with the analysis or
system firmware in your HP 64700 system.