Chapter 7: Using the Emulation Analyzer
Qualifying Trigger and Store Conditions
To trigger on a number of occurrences of some
state
• Use the occurs <#TIMES> after specifying the trigger state.
When specifying a trigger state, you can include an occurrence count. The
occurrence count specifies that the analyzer trigger on the Nth occurrence of some
state.
The default base for an occurrence count is decimal. You may specify occurrence
counts from 1 to 65535.
Examples
To trigger on the 20th occurrence of the call of the "update_system()" function
(main.c: line 102):
trace after address main."main.c": line 102 occurs 20
<RETURN>
208