Chapter 13: Error Messages
Terminal Interface Messages
1108
Unable to redefine label; used by emulation analyzer: <label>
Cause: This error occurs when you attempt to redefine an emulation trace label
which is currently used as a qualifier in the emulation trace specification.
Action: You stop the trace or must change the trace command before you can
redefine the label.
1109
Unable to redefine label; used by external state analyzer: <label>
Cause: This error occurs when you attempt to redefine an external trace label
which is currently used as a qualifier in the external state trace specification.
Action: You stop the trace or must change the trace command before you can
redefine the label.
1110
Unable to redefine label; used by external timing analyzer: <label>
Cause: This error occurs when you attempt to redefine an emulation or external
trace label which is currently being used as a qualifier in the external timing trace
specification.
Action: Remove the label from the external timing analyzer specifications, and
then redefine the label.
1301
External label in use: <label>
Cause: This error occurs when you attempt to select the external analyzer's
independent state mode while an external trace label is currently used as a qualifier
in the emulation analyzer trace specification.
Action: Remove any external trace label qualifiers from emulation trace
specifications before selecting the external analyzer's independent state mode.
1304
Analyzer trace running
Cause: This error occurs when you attempt to change the external analyzer mode
while a trace is in progress.
Action: Halt the trace before changing the external analyzer mode.