Unable to read registers in class: %s
Cause: The emulator was unable to read the registers you requested.
Action: To resolve this, you must look at the other status messages displayed.
Most likely, the emulator was unable to break to the monitor to perform the register
read. See message 608.
632
Unable to modify register: %s=%s
Cause: The emulator was unable to modify the register you requested.
Action: To resolve this, you must look at the other status messages displayed. It's
likely that emulator was unable to break to the monitor to perform the register
modification. See message 608.
634
Display register failed: %s
Cause: The emulator was unable to display the register you requested.
Action: To resolve this, you must look at the other status messages displayed. It's
likely that emulator was unable to break to the monitor to perform the register
display. See message 608.
636
Register not writable: %s
Cause: This error occurs when you attempt to modify a read only register.
Action: If this error occurs, you cannot modify the contents of the register with the
modify register command.
637
Register class cannot be modified: %s
Cause: You tried to modify a register class instead of an individual register.
Action: You can only modify individual registers. Refer to the display registers
command description for a list of register names.
640
Unable to reset
Cause: Target condition or system failure.
Action: Check target system, and run performance verification (Terminal Interface
pv command).