Chapter 13: Error Messages
Graphical/Softkey Interface Messages - Unnumbered
emulator logical name is located in the /usr/hp64000/etc/64700tab.net (or
64700tab) file.
Stepping aborted; number steps completed: <STEPS TAKEN>
Cause: Stepping aborted because <CTRL>c or software breakpoint was hit,
guarded memory was accessed, or some other kind of error occurred.
Action: See the error log display for any abnormal errors. Correct those errors and
then step again.
Stepping complete
Cause: Stepping was completed successfully.
Step count must be 1 through 999
Cause: You tried to use a step count greater than 999.
Action: Use a step count less than 1000.
Symbols not accessible, symbol database not loaded
Cause: You specified a trace list with values expressed using symbols defined in
the source code modules, such as source on, and the database file has not been
loaded into emulation. Example: display trace symbols on.
Timeout in emul700dmn communication
Cause: The host system could not start the emulation session because the HP 64700
emulator process ran out of time before the emulator could start.
Action: You must press end_release_system to exit this emulation session
completely; then start a new session. Make sure the host system is operating
properly, that all Softkey Interface software has been loaded correctly, and the data
communication switch settings on the emulator rear panel match the settings in the
/usr/hp64000/etc/64700tab.net (or 64700tab) file.
Trace file not found
Cause: You tried to load trace data file that does not exist.
Action: Find the correct name and path of the trace data file and try again.