HP 64767 User Manual page 440

Emulation/analysis
Table of Contents

Advertisement

Chapter 13: Error Messages
Graphical/Softkey Interface Messages - Unnumbered
Error: display size is <LINES> lines by <COLUMNS> columns. It must be at
least 24 by 80.
Cause: You tried to specify an incorrect window size.
Action: Set the window size accordingly, then start the emulation session. The size
of the window must be a minimum of 24 lines (rows) by 80 columns to operate an
emulation session.
Error in configuration process
Error starting configuration process
Cause: Unexpected configuration error.
Action: Verify proper software installation and call your HP 64000 representative.
Fatal error from function <ADDRESS OF FUNCTION>
Cause: This is an unexpected fatal system error.
Action: Cycle power on the emulator and start again. If this is a persistent problem,
call your HP 64000 representative.
File could not be opened
Cause: You tried to store or load trace data to a file with incorrect permission. Or
the analyzer could not find the file you specified, or else there were already too
many files open when you entered your command.
Action: Check the directory and file for correct read and write permission. Specify
a file that is accessible to the analyzer. Close the other files that are presently open.
File perf.out does not exist
Cause: You tried to execute the "restore" command to continue a previous software
performance measurement, and the SPMT software found that no
"performance_measurement_end" command was previously executed to create a
file from which "restore" could be performed.
Action: Execute a new SPMT measurement.