Detailed Description - General
Network Time Protocol (NTP) for XPEK Systems
The Network Time Protocol (NTP) on XPEK systems allows the MCU to synchronize the
internal MCU control unit's clock with an external NTP server. Accurate time calculation is
essential for cascaded or recurring conferences.
Detailed Description
The time synchronization protocol used in MGC version 7.5 is SNTP (Simple Network
Time Protocol), a version of the NTP protocol used by Microsoft's W32Time Service. NTP
servers use the time-zone independent Universal Time Coordinated (UTC) standard to
synchronize networked computers. UTC is the current official standard that is based on an
atomic clock and ensures uniform time calculation for networks.
To synchronize MCU time with the NTP Server:
1.
Right-click the MCU icon and click MCU Time.