MGC Release Notes - Version 7.5
SIP Factory
SIP Factory is a new conferencing entity that enables SIP endpoints to create an arbitrary
number of ad hoc conferences and automatically connect to the new conferences.
Detailed Description
When the Sip Factory is created, using SIP call control means, a globally routed
Conference Factory URI can be allocated and published. When a SIP endpoint calls this
URI, and the call is established successfully, a new conference is automatically created and
the endpoint joins the conference. The conference automatically ends when the conference
creator leaves the conference. All other participants are invited to the conference using the
SIP REFER method.
To create a SIP Factory:
A conference Profile must be defined in the MCU before creating a SIP Factory. The Profile
should be set to Auto Terminate when the Chairperson exits the conference.
1.
2.
3.
38
Expand the MCU tree.
Right-click the Meeting Rooms, Entry Queues & SIP Factories icon and then click
New SIP Factory.
The SIP Factory dialog box opens.
Define the following parameters:
— Name - Enter the SIP Factory Name. This is the name that will be used as part of
the URI (together with the domain name) dialed by the SIP endpoint to initiate the
conference.