8.92. PEQOF -- Set Frequency Parameter for Specified
Parametric EQ Output Stage
This command sets or queries the frequency parameter (in Hz) for the parametric equalizer (EQ)
filters on output channels 1, A, and B . Each channel has five bands of parametric EQ that can be
independently controlled.
The minimum and maximum values for the frequency parameter are 20 and 20000, respectively.
For filter types that have a center frequency (e.g., parametric), this parameter specifies the center
frequency. For filter types that have a cutoff frequency (e.g, highpass, lowpass, etc.), this parameter
specifies the cutoff frequency.
This command has the same format and restrictions as the
parameter, the frequency, is specified instead of all the parameters. See the
more information. To set the frequency parameter for an input parametric EQ filter, use the
command. To set all the parameters for an input parametric EQ filter, use the
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example
Q01PEQOF1,2,1250
Q01PEQOFB,1,?
8.93. PEQOG -- Set Gain Parameter for Specified Parametric
EQ Output Stage
This command sets or queries the gain parameter (in dB) for the parametric equalizer (EQ) filters on
output channels 1, A, and B . Each channel has five bands of parametric EQ that can be
independently controlled.
The minimum and maximum values for the gain parameter are -20 and 20, respectively.
This command has the same format and restrictions as the
Description
Set frequency of parametric
EQ on output 1 , band 2 to
1250 Hz.
Query current frequency
setting of parametric EQ on
output B , band 1.
command except that only one
PEQOA
Status Message
Q01PEQOF1,2,1250
Q01PEQOFB,1,f , where f is the current
setting of the frequency parameter for the
parametric EQ on output B , band 1. If the
frequency parameter of this filter is set to the
same value given in the example above, then
the status message will be
Q01PEQOFB,1,1250 .
command except that only one
PEQOA
command for
PEQOA
PEQIF
command.
PEQIA