Toggle enabled state of modem initialization
Q01MINI2
string.
Query enabled state of modem initialization
Q01MINI?
string.
8.72. MINISTR -- Set Modem Initialization String
This command is used to set or query the modem initialization string. The string can be a maximum
of 32 characters long. The recommended modem initialization string for the Vortex is:
ATF1E0&B1S0=2
This can be set via the following command.
Q01MINISTRATF1E0&B1S0=2
Whether or not the modem initialization string is sent at power-up is controlled via the
command.
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved
each time it is changed. It will retain its value after power-down. Since this command writes to non-
volatile memory, there will be a delay before an acknowledgment is returned.
Example
Q01MINISTRATF1E0&B1S0=2
Q01MINISTR?
8.73. MMUTE -- Mute Crosspoint in Main Matrix or
Submatrix
This command sets or queries the mute status of one or more crosspoints in either the main matrix or
one of the EF Bus submatrices.
This command is a matrix boolean command. See
on this type of command.
Description
Set modem initialization
string to
ATF1E0&B1S0=2.
Query current modem
initialization string.
Section 6.4
Q01MINIx , where x is 0 or 1 depending
on the current enabled state of the
modem initialization string.
Q01MINIx , where x is 0 or 1 depending
on the current enabled state of the
modem initialization string.
Status Message
Q01MINISTRATF1E0&B1S0=2
Q01MINISTR<string> , where
<string> is the current modem
initialization string. If this command was
sent after the above example, then the
status message would be
Q01MINISTRATF1E0&B1S0=2 .