Amnomat -- Select Nom Attenuation On Each Output - Polycom Vortex EF2210 Program Manual

Rs-232 command set
Hide thumbs Also See for Vortex EF2210:
Table of Contents

Advertisement

for Automixer
This command sets the local maximum number of open mics (NOM) allowed for the specified
automixer. The NOM limit is a local limit, meaning that this limit applies only to the specific Vortex
that is is set on. In contrast, the
automixers with the same AMBUSID.
The first argument of this command specifies the automixer number (always 1 on the EF2210) to
adjust. The second argument specifies the NOM limit (always 1). Even though this is a channel
integer command, use of the wildcard for specifying the automixer number is not supported.
This command is not particularly useful on the EF2210 since there is only one mic on this device.
However, it is provided in order to be consistent with the command sets of the other Vortex devices.
This command is a channel integer command. See
on this type of command. The minimum and maximum values for this command are 1 and 64,
respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example
Description
Set local NOM for automixer 1 to a
Q01AMNOM11
maximum of 1 mics.
Query current local NOM limit for
Q01AMNOM1?
automixer 1.

8.22. AMNOMAT -- Select NOM Attenuation on Each Output

This command enables, disables, or queries NOM attenuation for the specified output (1, A, B). . NOM
attenuation is calculated as 10*log(Number of Open Microphones).
Remember that even though there is only one microphone on this device, other microphones can be
brought in via the W, X, Y, and Z busses. These signals will have NOM information carried with them
from the other devices, which is why NOM attenuation is provided at the outputs.
This command is a channel boolean command. See
on this type of command.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example
AMGNOM
Description
command is a global limit that applies to all linked Vortex
Section 6.3
Status Message
Q01AMNOM11
Q01AMNOM1x, where x is always 1, since
there is only 1 mic on this device.