Increase gate threshold for
manual gating threshold by 3 dB
Q01AMGATET1>3
for input channel 1.
Query gate threshold for manual
gating threshold for input
Q01AMGATET1?
channel 1.
8.17. AMGNOM -- Set Global Maximum Number of Open
Mics for Bus Automixer
This command sets the global maximum number of open mics (NOM) allowed for the specified bus
automixer. The NOM limit is a global limit, meaning that this applies to all bus automixers with the
same AMBUSID. In contrast, the
the EF2210.
The first argument of this command specifies the automixer number (always 1 in the EF2210) to
adjust. The second argument specifies the NOM limit (1-64). Even though this is a channel integer
command, use of the wildcard for specifying the automixer number is not supported.
This command is a channel integer command. See
on this type of command. The minimum and maximum values for this command are 1 and 64,
respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example
Description
Set global NOM for the automixer to a
Q01AMGNOM13
maximum of 3 mics.
Query current global NOM limit for
Q01AMGNOM1?
the automixer.

8.18. AMHOLD -- Set Automixer Hold Time

This command sets or queries the hold time (in milliseconds) for the automixer.
command is a local limit that applies to the local automixer in
AMNOM
Section 6.3
Q01AMGATET1x, where x is between 0 and
100 depending on the current setting of the
gate threshold for input channel 1. If this
command is issued after the example above,
then the status message will be
Q01AMGATET315.
Q01AMGATET1x, where x is between 0 and
100 depending on the current setting of the
gate threshold for input channel 1. If this
command is issued after the example above,
then the status message will be
Q01AMGATET115.
and
Section 6.2
Status Message
Q01AMGNOM13
Q01AMGNOM1x, where x is between 1 and
64 depending on the current setting of the
global NOM limit for the automixer.
for more information