on this type of command. The minimum and maximum values for this command are 0 and 8,
respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example
Description
Configure the automixer to be part
of the Bus Automixer having Bus ID
Q01AMBUSID12
2.
Configure the automixer to be part
of the Bus Automixer having Bus D
Q01AMBUSID10
0. This means that the automixer is
not part of any Bus Automixer.
Query the current Bus ID of the
Q01AMBUSID1?
automixer.
8.11. AMCHAIR -- Enable Chairman Mode for Specified
Automixer
This command enables, disables, or queries the chairman mode feature for the specified automixer.
The first argument in the command specifies the automixer number (always 1 for the EF2210) and
the second argument specifies whether chairman mode should be enabled, disabled, toggled, or
queried.
Even though this is a channel boolean command, use of the wildcard character for the automixer
number is not supported.
This command is a channel boolean command. See
on this type of command.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example
Description
Disable chairman mode for the
Q01AMCHAIR10
automixer.
Enable chairman mode for the
Q01AMCHAIR11
automixer.
Query current setting of chairman
Q01AMCHAIR1?
mode for the automixer.
Status Message
Q01AMBUSID12
Q01AMBUSID10
Q01AMBUSID1x, where x is a number
between 0 and 8 indicating the current Bus ID
of the automixer.
Section 6.3
and
Section 6.1
Status Message
Q01AMCHAIR10
Q01AMCHAIR11
Q01AMCHAIR1x, where x is 0 or 1 depending
on the current setting of chairman mode for
the automixer.
for more information