4.6 ADJUSTMENT OF COUNTER BLADES

Counter blades (1) must be slid into the tank in order to disintegrate light and dry materials -
figure (4.3). Otherwise, the feed charge will rotate with the same speed as the auger. The
counter blades are installed on the opposite sides of the tank.
FIGURE 4.3 Principle of counter blade adjustment
(1) counter blade, (2) pin with cotter pin
In order to tilt the counter blade into the tank interior, unlock cotter pin of pin (2) and slide the
counter blade to a selected working position. Insert the cotter pin and repeat the same
procedure for the counter blade on the opposite side of the tank. The experience in feed
preparation is required to set the counter blades properly. The setting of the counter blades
4.13