5.6

TRANSMISSION MAINTENANCE

Maintenance of the reduction gear is conducted during general inspection, change or topping
up gear oil. In the event of damage to the reducer, contact authorised service point in order
perform repairs.
First oil change must be made after the first 100 hours worked. The next oil change should
be made after 2,000 hours of the mixer feeder work or once a year.
ATTENTION
If the amount of transmission oil added in order to reach the correct level (after 100 hours)
is greater than 1.5 litres, it is an indication of transmission oil leakage. Please contact the
service centre for repair.
Oil change
Unscrew the bleed conduit plug (1) – figure (5.6) and expansion tank plug (2).
Unscrew drain plug (3).
Drain oil into an oil-resistant tight container, the container capacity should be
about 20 litres.
Clean the drain plug, replace the seal.
If the oil manufacturer recommends flushing transmission with washing
detergent, that operation should be performed according to the guidelines of
the oil manufacturer.
Tighten drain plug (3).
The drain plug contains a magnetic filter.