Tool List - FULTON Endura EDR Installation, Operation And Maintenance Manual

Condensing hydronic boilers 750,000 - 2,000,000 btu/hr featuring pure control
Table of Contents

Advertisement

SECTION 4
EDR-PURE-IOM-230608

Tool List

To complete routine preventative maintenance or repairs, certain tools and
supplies will be required that are not provided with the boiler. The quali ed
service technician should be prepared with the following tools and supplies.
ƒ
Digital Multimeter (DMM) with True RMS
ƒ
16GB or larger USB Flash Drive (FAT32 format only) with the current PURE
Control™ Software
ƒ
Maintenance Checklist Form and Pen/Pencil
ƒ
Slack Tube® Manometer or Equivalent
ƒ
GAS-Mate® Combustible Gas Leak Detector or Equivalent
ƒ
Calibrated Flue Gas Analyzer
ƒ
Calibrated Calipers
ƒ
Calibrated Torque Wrench
ƒ
Calibrated Torque Screwdriver with T25 Drive
ƒ
Pipe Wrenches
ƒ
Crescent Adjustable Wrench
ƒ
Blade (Flat-Head), Phillips, and Torx Screwdriver Sets
ƒ
Close Quarters Angled Phillips Screwdriver
ƒ
Socket Wrench
ƒ
SAE Socket Set
ƒ
SAE Deep Socket Set
ƒ
Metric Socket Set
ƒ
Metric Deep Socket Set
ƒ
SAE Wrench Set
ƒ
Metric Wrench Set
ƒ
9/16" Crowfoot Wrench
ƒ
Metric Allen/Hex Key Wrench or Socket Set
ƒ
Grade #00 Very Fine Steel Wool Pad
ƒ
Super O-Lube or Equivalent
ƒ
Permatex® Dielectric Grease or Equivalent
ƒ
Loctite® LB8150 Silver Grade Anti-Seize or Equivalent
ƒ
Loctite® C5-A Copper Anti-Seize or Equivalent
ƒ
Hercules® Megaloc® Thread Sealant or Equivalent
ƒ
Portable Shop Vacuum
ƒ
Compressed Air with Blow Gun Nozzle
ƒ
Appropriate Personal Protective Equipment (PPE)
ƒ
Lockout-Tagout (LOTO) Tags
Questions? Please Contact Your Local Manufacturer's Representative
MAINTENANCE
!
WARNING
All information in this manual is for
reference and guidance purposes,
and does not substitute for required
professional training, conduct,
and strict adherence to applicable
jurisdictional/professional codes and
regulations.
Prior to any maintenance concerning
electrical components of this
equipment, ensure electrical supply
to the equipment is disconnected.
Label all wires prior to disconnection;
wiring errors may cause improper
and hazardous operation.
Follow all proper lockout/tagout
procedures for service.
Before beginning any maintenance,
ensure area is free of any combustible
materials and other dangers.
What to do if you smell gas:
Do not try to light the appliance.
Do not touch any electrical switch.
Do not use any phone in the building.
Leave building and contact gas
supplier from neighbor's phone. If you
cannot reach gas supplier, phone the
re department.
After initial start-up by quali ed
personnel, linkage, control settings,
and fuel pressures should not be
readjusted.
4
CAUTION
All maintenance procedures should
be completed by trained personnel.
Appropriate training and instructions
are available from the Fulton Service
Department at (315) 298-5121 or
your local Fulton Heating Solutions
Representative.
In order to meet warranty conditions,
ensure all appropriate maintenance
activities are performed.
4-3

Advertisement

Table of Contents
loading

Table of Contents