4 Controlling Operation and Data Output with RS-232C
Wire color
Green
Yellow
None
V430-W8
Signal Name Color
SD
Black
RD
Purple
0V *1
Blue
Use a shielded cable. Up to 15m cable length.
*1. 0V is shared with the 0V for F440-F/F430-F power supply supply, so please branch it.
*2. Please connect according to your device specifications.
Example: When using Omron Serial Communication Unit
4-1-3

Communication Settings (Serial (RS-232C))

RS-232C Communication Settings on the Smart Camera
Set the RS-232C communications settings on the smart Camera according to the settings on the PLC
or other external device.
1
Set the Baud Rate, Parity, Stop Bit, and Data Length according to the RS-232C communication
settings of the external device to connect to.
4-4
Pin No.
Signal Name
3
DEFAULT
4
NEW MASTER
-
(Shield)
External Device
to Connect
Signal Name Pin No.
RxD (RD)
TxD (SD)
GND
CJ1W-SCU22
Signal Name Pin No.
RxD (RD)
TxD (SD)
GND
F440-F/F430-F/F420-F Series Smart Camera User's Manual for Communication Settings (Z444)
Default
This is not used for the F440-F/F430-F.
New Master
This pin is used when the Decode Tool is used
to learn new match strings.
To enable the learning function, turn ON pin
number 4 with the Auto Teaching option set to
"Learn Match Strings" in the Advanced Set-
tings of the decoder tool .
If the trigger setting is digital, a measurement
trigger is also entered.
Shield
*2
*2
*2
3
2
9
Function