Wiring And Electrical Specifications For Parallel I/O [F440-F/F430-F] - Omron MicroHAWK F440-F Series User Manual

Smart camera
Hide thumbs Also See for MicroHAWK F440-F Series:
Table of Contents

Advertisement

2-1-2
Wiring and Electrical Specifications for Parallel I/O [F440-F/F430-
F]
The following is the wiring diagram of the power cable to connect to the smart camera (All V430-W8).
Smart Camera
Colors for each wire
Wire color
Brwon
2
Blue
7
Red
8
Red striped
12
White
1
Black
9
Purple
10
Gray
5
Gray striped
11
Pink
6
Green
3
Yellow
4
None
-
F440-F/F430-F/F420-F Series Smart Camera User's Manual for Communication Settings (Z444)
2 Controlling Operation and Data Output with Parallel
Pin No.
Signal Name
24V
0V
COM_IN
COM_OUT
TRIG
RD
SD
OUTPUT1
OUTPUT2
OUTPUT3
DEFAULT
NEW MASTER
(Shield)
Brown
24V
Blue
0V
Red
COM_IN
Red striped COM_OUT
White
TRIG
Black
RD
Purple
SD
Gray
OUTPUT1
Gray striped OUTPUT2
Pink
OUTPUT3
Green
DEFAULT
Yellow
NEW MASTER
None
(Shield)
Power supply
GND
Common Input Signals (Input Common)
Common Output Signals (Output Common)
Measurement Trigger Input (When the trigger
setting is selected sensor)
Receive Data
Send Data
Output1
Output2
Output3
Default
This is not used for the F440-F/F430-F.
New Master
This pin is used when the Decode Tool is used
to learn new match strings.
To enable the learning function, turn ON pin
number 4 with the Auto Teaching option set to
"Learn Match Strings" in the Advanced Set-
tings of the decoder tool .
If the trigger setting is digital, a measurement
trigger is also entered.
Shield
Function