Setting item
Originator variable
Size (Originator variable)
Connection type
Precautions for Correct Use
If the CIO memory area that holds contents were not specified when I/O memory addresses are
specified for communication areas, the information in each communication area will be cleared
when the operating mode of the PLC is changed.
3-1-6

Output Setting Example

1. Set the GO_Online bit to TRUE to be ready to start measurement.
2. The PLC (User) changes the Trigger bit assigned to the memory area (Output Area) of the PLC in
advance from FALSE to TRUE.
3. When the PLC changes the Trigger bit to TRUE, the smart camera executes an imaging process.
4. After completion of the imaging process the smart camera stores the data in the specified memory
area (Input Area) of the PLC.
[Output Data Example]
The number of read characters is output to STRING1_Length and the read characters are output to
STRING1.
F440-F/F430-F/F420-F Series Smart Camera User's Manual for Communication Settings (Z444)
3 Controlling Operation and Data Output with Ethernet
Variable defined on the PLC
320 bytes
Point to Point connection
Description
3
3-13