Setting item
Pulse Width
6
Select the outputs to use for Output 2 and Output 3.
In this example, select Inspection Passed for Output 2 and Inspection Failed for Output 3. Set
the Pulse Width, Mode, and State for the outputs.
Setting item
Pulse Width
Mode
State
7
Save the settings and download the job to the smart camera.
2-1-8
Use as Ext.Illumination Strobe
Outputs the signal used to illuminate with external lighting.
F440-F/F430-F/F420-F Series Smart Camera User's Manual for Communication Settings (Z444)
2 Controlling Operation and Data Output with Parallel
Setting value
1 to 10000 (ms)
Enter the time during which the ON state is held.
Setting value
1 to 10000 (ms)
Set this only when the Mode is Pulse.
Enter the time during which the ON state is held.
•
The output status will be set at the end of inspection cycles.
Latched
•
•
Latched
Pulsed
The status will remain latched until the end of the next in-
spection cycle.
•
Pulsed
The output will be ON during the time set in Pulse Width.
•
•
Active High
Active High
•
Active Low
The state will be Low when output is OFF. The state will be
High when output is ON.
•
Active Low
The state will be High when output is OFF. The state will
be Low when output is ON.
Description
Description
2
2-11