A-3 Serial Command
Serial commands can be sent via TCP port, AutoVISION terminal, or HyperTerminal.
Precautions for Correct Use
The MicroHAWK MV-4000 does not support focus commands.
Serial Command Syntax
• Command parameters include required parameters that must be always specified and option pa-
rameters that may be specified as needed.
• Insert a space between the command and the parameters.
• Insert a space between each parameter.
• Add a delimiter <CR> to the end of the command or parameter.
• No space is required between the parameter and the delimiter.
• Option parameters may be omitted.
• <CR> indicates a Carriage Return.
• <LF> indicates a Line Feed.
• <ETX> indicates the End of Text.
AUTOCAL
Initiates camera calibration of gain, exposure, and focus. Each parameter is independent. Ranges are
device-dependent.
Precautions for Correct Use
AUTOCAL only functions when the camera is OFFLINE.
 Command Format
AUTOCAL -exp=SettingValue -expval=SettingValue -gain=SettingValue -gainval=SettingValue -fo-
cus=SettingValue -focval=SettingValue<CR>
• Insert a space between the command and the parameters.
• Insert a space between each parameter.
• Add a delimiter <CR> to the end of the command or parameter.
• No space is required between the parameter and the delimiter.
• Refer to the table below for the setting values.
Required Parameter
None
Option parameter
A-4
F440-F/F430-F/F420-F Series Smart Camera User's Manual for Communication Settings (Z444)