A-2 PROFINET Information
A-2-1
PROFINET I/O Identity
The table below shows the PROFINET device ID information for the F440-F/F430-F.
• Vendor ID
Omron Microscan's Systems, Inc. Vendor ID is 0x0257.
• Device ID
F430: 0x7000
F440: 0x7005
• Vendor name
Vender name is OMRON MICROSCAN SYSTEMS, INC.
• Device function
Device function is as follows:
• MainFamily = General
• ProductFamily = SmartCamera
A-2-2
GSDML File
Contact your Omron representative for the GSDML file.
A-2-3
Connection Properties: RT Cyclic Messaging
Odd slot numbers are input to the PLC, even slot numbers are output from the PLC.
Maximum data size in either direction is 518 bytes. The data size can be reduced by removing slots
that are not used.
Cycle update time for F430-F: 16 ms
Cycle update time for F440-F: 16 ms
Additional Information
The GSD file contains element MinDeviceInterval, which is 512. Multiply this by 31.25 μs. This
is the cycle time. See the PROFINET GSDML specification for more information.
F440-F/F430-F/F420-F Series Smart Camera User's Manual for Communication Settings (Z444)
Appendices
A