Cm150 - Inspection Of The Pneumatic System - Index MS32-6.3 Operating Instructions Manual

Table of Contents

Advertisement

CM150
- Inspection of the pneumatic system
Orientation
66
Carrying out the maintenance activities described below requires
special knowledge. For this reason, these maintenance activities
must only be carried out by staff that has received adequate training
by the machine manufacturer!
Operating fluids such as hydraulic fluids, cooling lubricants, lubricating greases/oils
are also subject to degradation or aging as the components involved in this process,
and must therefore be serviced, refilled or replaced at regular intervals.
To ensure trouble-free operation, periodic checks of the pneumatic system are
necessary.
-
Check pressure setting on pressure gauge.
-
Check fluid lines.
-
Check silencers.
-
Drain off condensate.
-
Check filters, replace if necessary.
Example: Pneumatic maintenance unit (Festo) MS32-6.3 MS24-6
1
Compressed air connection
2
Switch-on valve, manually operated
a
Filter regulating valve (factory setting 6 bar/ min. 3.0 bar or 4.0 bar)
b
Fire shutter branch module
b'
Fire protection system choke
c
Switch-on valve (electrically operated) with silencer
d
Pressure regulation
e
High-precision pressure regulating valve (factory set to 0.3 bar) with pressure monitoring
f
Pressure distribution system
f
Compressed air system, top
1
f
Compressed air system, bottom
2
g
"Leakage oil extraction" valve
h
"Control auxiliary air" valve
i
"Control auxiliary air" pressure monitoring
(*)
Check by manually pushing (using a ballpoint pen or similar) the yellow button of the switch-on valve (c)