Index MS32-6.3 Operating Instructions Manual page 24

Table of Contents

Advertisement

Requirement
Procedure
20
Example: Pneumatic maintenance unit (Festo) MS32-6.3 MS24-6
1
Compressed air supply line
2
Shut-off valve, manually operated
a
Filter regulating valve (factory setting 6 bar/ min. 3.0 bar or 4.0 bar)
b
Fire shutter branch module
b'
Fire protection system choke
c
Switch-on valve (electrically operated) with silencer
d
Pressure regulation "loading magazine"
e
High-precision pressure regulating valve (factory set to 0.3 bar) with pressure monitoring
f
Pressure distribution system
f
Compressed air system, top
1
f
Compressed air system, bottom
2
g
"Leakage oil extraction" valve
h
"Control auxiliary air" valve
i
"Control auxiliary air" pressure monitoring
(*)
Check by manually pushing (using a ballpoint pen or similar) the yellow button of the switch-on valve (c)
Power off the machine to depressurize the pneumatic system and
secure against accidental switching on.
1. Check fluid lines. Fluid lines must be checked for damage. Pre-damage such
as kinks or abrasions should be logged and replacement should be initiated.