Am135 - Removing Clamping Element Holder - Index MS32-6.3 Operating Instructions Manual

Table of Contents

Advertisement

Maintenance Summary - Care activities
AM135
- Removing clamping element holder
Orientation
Maintenance Instructions
MS32-6.3
DIM105EN - 26.04.2022
Due to different requirements and/or specifications of the respective
manufacturers, be sure to review the respective manufacturer's
documentation!
Removal of the clamping element holder is necessary as part of
regular cleaning of the machine. To support dismantling that is easier
on the bearings, INDEX requires the use of the integrated forcing pins
in the clamping element holder when dismantling the clamping
element holder.
To avoid putting strain on the spindle bearings, it should
generally be possible to remove each clamping device in a way
that is easy on the bearings without using a rebound hammer
(Zocker). Therefore, forcing pins or removal tools must be
provided for all clamping devices.