A043 - Check Pneumatic System (Visual Inspection) - Index B400 Operating Instructions And Maintenance Instructions

Table of Contents

Advertisement

Maintenance Summary - Care activities
A043
- Check pneumatic system (visual inspection)
Orientation
Maintenance Instructions
B400
DIE150EN - 05.06.2019
To ensure trouble-free operation, periodic checks (visual inspection) of the
pneumatic system are necessary.
-
Check system pressure and sealing air settings.
-
Check supply and fluid lines.
-
Check silencers.
-
Drain condensate (not applicable to auto-drain).
-
Check pressure setting on the pressure differential monitoring pressure gauge.
Example: Pneumatic maintenance unit B400 (by FESTO)
Due to different requirements and/or specifications of the respective
manufacturers, be sure to review the respective manufacturer's
documentation!
The following components are used on the system maintenance unit (X) and the
extension for sealing air on the glass scales (Y):
-
X System maintenance unit
-
1. Switch-on valve (manual)
-
2. Pressure regulating valve system pressure 6 bar
-
3. Pressure gauge for system pressure
-
4. Filter insert with retained particle size 40 µm with automatic condensate
drain
-
5. Filter insert with retained particle size 5 µm with automatic condensate drain
-
6. Branch module
-
7. Electrically actuated switch-on valve
-
8. Pressure sensor for system pressure
-
Y Expansion of "glass scales" lock-out air