A037 - Check Pneumatic System (Visual Inspection) - Index G220 Operating Instructions And Maintenance Instructions

Table of Contents

Advertisement

Maintenance Summary - Care activities
A037
- Check pneumatic system (visual inspection)
Orientation
Maintenance Instructions
G220
DIE017EN - 05.06.2019
To ensure trouble-free operation, periodic checks (visual inspection) of the
pneumatic system are necessary.
-
Check oil level at oiler (optional).
-
Check system pressure and sealing air settings.
-
Check supply and fluid lines.
-
Check silencers.
-
Drain condensate (not applicable to auto-drain).
-
Check pressure setting on the pressure differential monitoring pressure gauge.
Example: Pneumatic maintenance unit (by FESTO)
Due to different requirements and/or specifications of the respective
manufacturers, be sure to review the respective manufacturer's
documentation!
The following components are used on the system maintenance unit (X) and the
extension for sealing air on the glass scales (Y):
1. Switch-on valve (manual)
2. Pressure regulating valve for system pressure 6–8 bar
3. Pressure gauge for system pressure
4. Filter insert with retained particle size 40 µm with automatic condensate drain
5. Filter insert with retained particle size 5 µm with automatic condensate drain
6. System pressure monitoring
7. Electrically actuated switch-on valve
8. Pressure sensor for pressure differential monitoring
9. Microfilter insert with retained particle size 1 µm with automatic condensate
drain
10. Filter insert with retained particle size 0.01 µm with automatic condensate drain
11. Activated carbon filter no automatic condensate drain