Maintenance Summary - 8 Years
Maintenance Instructions
MS32-6.3
DIM105EN - 26.04.2022
11.
Example: MS32-6.3 window pane of work area door 10 (Fig. 12)
Example: MS32-6.3 window pane of work area door 8 (Fig. 13)
Align work area door. (Horizontal adjustment at the top) Loosen all M6
screws (6x) of the two roll pins (r – left and right). The roll pin can then be
swiveled around one of the three screws (see Fig.: 13). The other two move in
an arc-shaped slotted hole. Once the adjustment is complete, retighten the 6
screws on both roll pins.
12. Check guard switch setting, and readjust if necessary. After completion of the
adjustment work on the design pane and the work area door, the guard switch
setting must be checked and readjusted if necessary. Close the work area door
and press the Guard Lock key. If the door can be locked and not opened again
manually, the setting is correct. However, if a fault is indicated on the controller
and the door can be opened manually, the guard switch must be readjusted.
The procedure for mounting and dismounting the design pane and the
93