Place the new right hand plaque in
9.
position. Make sure that the centre
section of the combination gasket is
between the two plaques. If there is any
play between the plaques and the end
retaining flanges, push the plaques firmly
to the left squeezing the centre section of
the combination gasket between the two
plaques. Any gap should be between the
right side of the plaque and the right
side-retaining flange.
Fit the front and rear plaque clamping
10.
strips. Make sure that the plaques are as
far to the left as possible. . It is important
that the left side plaque is accurately
positioned so that it has the correct
relationship to the pilot. Fully tighten the
clamping strips.
Refit the coals as described in section
11.
12 of this manual. Refit the bottom
castings.
16.15 To Remove the Appliance
from the Fireplace
Remove the burner unit - See section
1.
16.6.
If the fire retention is as method 1 (See
section 8.1 of installation instructions),
remove the screws.
If the fire retention is as method 2 (See
section 8.2 of installation instructions), slacken the hexagonal adjusters on the cable
retainers and unscrew the thumbscrews to release the cables.
Refit as described in the relevant installation sections. Make sure gas soundness,
2.
sealing, spillage test and performance are satisfactory.