figure 13. Secure the fireback spacers
using the screws removed previously
and the two supplied with the fire.
5.
This appliance is supplied with
a flue restrictor for use where the flue
draught is excessive. The restrictor
must NOT be fitted where a
precast flue or a flue liner is used.
For all other installations the
restrictor should be fitted. There may
however, be certain exceptional
circumstances where fitting the
restrictor causes the fire to fail the
spillage test. In such cases the
restrictor will have to be removed.
After removal conduct the
spillage check again.
The restrictor is packed loose
with the appliance and is fixed
with three screws. See figure 14.
6.
There is a length of self
adhesive foam seal supplied with
the fire. This will need to be fitted
to the outer rear edges of the side
and top flanges of the convection
box. Cut a 485mm length of foam
seal. Be careful not to stretch the
seal when measuring. Remove the
protective backing from the foam
seal and fit this to the rear of the
top flange (See figure 15). Cut
two 580mm lengths. Fit these to
the rear outer edges of the side
flanges. Ensure that there is no
gap between the foam seals where
they meet at the top flange (See
figure 15)
INSTALLER'S GUIDE
Figure 14. Flue Restrictor
Figure 15. Fitting the foam seal