16.12 To Remove the Gas Flow Rate Controller

See figure 64.
Remove the burner unit - See
1.
section 16.6.
If lying the burner on its back,
2.
unscrew and remove the two ceramic
support brackets from the top of the
burner unit. This will avoid damage
to the brackets and the worksurface
(see figure 59)
Detach the microswitch cover -
3.
See section 16.1 paragraph 2.
Detach the shut-off tap as detailed
4.
in section 16.11 paragraphs 2-6.
Detach the burner pipe from the
5.
controller. Support the controller
while detaching to prevent excessive
strain.
Remove the nut and washer
6.
securing the control pivot bracket to
the controller at the front. Support
the pivot bracket while removing the nut
to prevent possible damage to the
microswitch.
Remove the hexagonal bolt securing
7.
the control pivot bracket to the controller
at the rear.
Detach the control pivot bracket.
8.
Remove the hexagonal nut securing the
9.
controller to the front mounting bracket
and remove the flow rate controller.
Refit in the reverse order.
10.

16.13 To Remove the Main Burner Injector

See figure 65.
Remove the burner unit - See section 16.6.