7 P R E P A R I N G A P P L I A N C E F O R
IMPORTANT
Before continuing with the installation
of this gas fire the aeration setting on
the burner must be checked. This has
been factory set. See section 16
(Servicing and parts replacement).
1.
Detach the burner unit from the
convection box by removing two screws -
See figure 11. Lift the burner unit clear.
2.
Fit the two "U" section seals to the bottom
edges of the convection box side flanges. See figure
12.
3.
For concealed connection only: There are two
removable circular panels at the rear of the
convection box. Decide which one of these is to be
used for rear entry. Using a suitable tool apply
pressure to the centre of the removable circular
panel. There is a grommet in the installation kit
supplied with the fire. Fit this into the hole.
Pierce the grommet to allow the pipe to pass
through it. The grommet should envelop the
pipe. If the hole is larger than the pipe, seal it
with tape. Do not pierce the grommet unless
the supply pipe is to pass through it.
4.
The appliance is supplied with two
fireback spacers. Do not fit the fireback
spacers if the fire is to be installed into a
precast or clay flue block system as in section
2.2.2.These should extend backwards to ensure
sufficient clearance from the back of the
fireplace. Remove the label and retaining
screws from the rear sides of the convection
box. Position the fireback spacer as shown in
INSTALLER'S GUIDE
I N S T A L L A T I O N
Page 18
Figure 11. Burner Attachment Points
Figure 12. "U" Seals
Figure 13. Fireback Spacers