1 4 F U L L O P E R A T I N G C H E C K S
14.1

Check the Control Settings

The control position markings on the front surround are shown in figure 48.
Please note:
When first turned on from cold, the flames will appear predominantly blue.
When operating the fire for the first time, some vapours may be given off which could
set off smoke alarms in the vicinity. These vapours are quite normal with new appliances.
They are totally harmless and will disappear after a few hours use.
Make sure the slider button is at the off position (At topmost position marked "O" on
1.
the front surround).
Open the isolating valve on the inlet elbow.
2.
Slide the button to the bottom (ignition) position marked . Retain in this position to
3.
ignite the pilot. The burner should ignite at its lowest setting within 4 seconds of the pilot
igniting. Keep at this position for a further 10 seconds to allow the pilot flame to
stabilise.
Release the button. The button should automatically spring up to the low heat
4.
position. If the flames go out at this stage or when
checking the rest of the setting positions, try the full
lighting sequence again. If the flames fail after two
attempts, investigate the pilot unit.
Gradually slide the button up to increase the burner
5.
setting. The burner should be at its maximum setting at
the high heat position shown in figure 48. You should
feel a check to the button movement at this position.
Slide the control button up past the high heat position
6.
to the off ("O") position at the top of the slide slot. Both
pilot and main burner should go out. While cooling the
coals may make some crackling noises. This is quite
normal.